Start a conversation

Comparing DIC & FEA

This document outlines the recommended workflow for quantitatively comparing full-field measurements from VIC-3D 11 with the simulated results from a finite element (FE) model. Carefully following these procedures in VIC-3D helps ensure the resulting differences between the DIC and FEA data reflect real measurement-vs model discrepancies that can be used for validation or model updating (e.g., FEMU).


A full example data set, including an Abaqus model can be downloaded here.


The plugin for exporting Abaqus results can be installed following instructions on the page linked here.


The utilities for converting Ansys results can be installed following instructions on the page linked here.

Comparing_DIC_and_FE.pdf

  1. 3440 KB
  2. View
  3. Download
Choose files or drag and drop files
Was this article helpful?
Yes
No
  1. Ian Adkins

  2. Posted
  3. Updated

Comments